Efficient cooling solution for Interlaken Hospital

Interlaken Hospital is investing in its future and adapting its infrastructure to meet modern requirements. In the new building now replacing the oldest complex on the hospital campus, a CTA standard chiller ensures everything is at the right temperature – in summer and in winter.
DJI 20241216105935 0063 D ret 1500x112

The new building replaces the oldest complex on the Interlaken Hospital campus.

Optimal year-round operation

When running a hospital, constant, pleasant temperatures are essential both for patients’ health and a good working environment for the staff. The new building, which replaces Block E in the oldest complex, also features a modernised cooling system. The solution chosen was standard chiller i-FX2-W-04. This system is marked by its high energy efficiency and its outstanding heat recovery. In summer, the waste heat generated in service is kept and used, e.g. for heating water. At times between seasons, waste heat is also used for heating. Waste heat usage reduces energy consumption and boosts the system's overall energy efficiency.

High power efficiency under partial load

One particular feature is that the chiller is run partially flooded, has a wide output range and can also handle high flow temperatures for using waste heat. This is achieved using two dual-rotor screw compressors with an inbuilt frequency converter and variable Vi technology that allows seamless power adjustment from 20 to 100 per cent. Considering that the chiller is a flooded system, it requires very little refrigerant. The combination of optimum efficiency and reduced refrigerant levels makes this standard chiller particularly innovative and sustainable under partial load. Two independent cooling circuits also ensure maximum operational reliability.

 G0A7209 ret 1500x100
Matthias Steiner,Project manager air conditioning/refrigeration

Super collaboration

The collaboration between the installer, the designer and CTA ran like clockwork. The chiller was even delivered ahead of schedule, saving costs.

The i-FX2-W-04 chiller

The hydraulically reversible water/water chiller and heat pump achieves very impressive performance and is marked by the low level of refrigerant it requires. Two speed-regulated Bitzer screw compressors with regulated Vi ensure that the system always matches the building's cooling requirements. The newly developed hybrid vaporiser technology means that the machine can achieve the same energy efficiency as a flooded system but using considerably less refrigerant.

 G0A7239 ret 1500x99

The chiller installed

snowflake

Water-cooled, hydraulically reversible chiller unit

snowflake

Speed-regulated screw compressor

snowflake

ESEER EN14511 of 7.81 und COP of 4.41

snowflake

Heating output range (product range): 430–1280 kW

snowflake

Cooling output range (product range): 398–1241 kW

Comprehensive range of services

Once CTA chillers, air conditioning units or large heat pumps are installed and in operation, our service team will ensure that they run perfectly and optimally for years to come. Find out more about our service contracts here - from the management contract to the flat-rate maintenance contract to the all-round protection CTAprotect with extended warranty.

More about the service

Contributors

  • Design: Eicher + Pauli, Bern

  • Installation: Adolf Krebs, Thun

  • Client: Interlaken Hospital

  • Chiller and system supplier: CTA AG, Münsingen

Nicolas Gfeller DSC0371_1000x667

Which upcoming project can we talk shop with you about?

Get in touch with us now.

Contact CTA experts

Company

Locations / ContactAbout UsNewsMedia & DownloadsCareer

Contact

CTA Ltd.

Hunzigenstrasse 2

CH-3110 Münsingen

Tel. +41 31 720 10 00info@cta.ch

Copyright © 2022 CTA Ltd.

General Terms and Conditions of BusinessGeneral Terms of PurchaseGTC Recruitment ServicesData ProtectionCookie Consent